Electrical Specifications; Ac Voltage Measurement - Fluke 1587 FC User Manual

Hide thumbs Also See for 1587 FC:
Table of Contents

Advertisement

Electrical Specifications

AC Voltage Measurement

Accuracy (all 1587 models)
Range
600.0 mV
6.000 V
60.00 V
600.0 V
1000 V
[1]
1 kHz bandwidth.
Low-Pass Filter Voltage (all 1587 models)
Range
600.0 mV
6.000 V
60.00 V
600.0 V
1000 V
Resolution
0.1 mV
0.001 V
0.01 V
0.1 V
1 V
Resolution
0.1 mV
0.001 V
0.01 V
0.1 V
1 V
50 Hz to 60 Hz
±(% of Rdg + Counts)
±(% of Rdg + Counts)
±
(1 % + 3)
±
(1 % + 3)
±(1 % + 3)
±(1 % + 3)
±(2 % + 3)
50 Hz to 60 Hz
±(% of Rdg + Counts)
±(% of Rdg + Counts)
±(1 % + 3)
±(1 % + 3)
±(1 % + 3)
±(1 % + 3)
±(2 % + 3)
Insulation Multimeter
Electrical Specifications
60 Hz to 5000 Hz
±
(2 % + 3)
±
(2 % + 3)
±(2 % + 3)
[1]
±(2 % + 3)
[1]
±(2 % + 3)
60 Hz to 400 Hz
+(2 % + 3)
-(6 % - 3)
+(2 % + 3)
-(6 % - 3)
+(2 % + 3)
-(6 % - 3)
+(2 % + 3)
-(6 % - 3)
+(2 % + 3)
-(6 % - 3)