15. MANUAL AUTO OPERATION (Indoor unit body operation)
If MANUAL AUTO Button is set, the operation is controlled as shown in Table 12.
If the remote control is lost or battery power dissipated, this function will work without the remote
control.
(Table 12)
OPERATION MODE
FAN CONT. MODE
TIMER MODE
SETTING TEMP.
SETTING LOUVER
SWING
16. FORCED COOLING OPERATION
Forced cooling operation is started when pressing MANUAL AUTO button for 10 seconds or more.
During the forced cooling operation, it operates regardless of room temperature sensor.
Operation LED and timer LED blink during the forced cooling operation. They blink for 1 second ON
and 1 second OFF on both operation LED and timer LED (same as test operation).
Forced cooling operation is released after 60 minutes of starting operation.
The FORCED COOLING OPERATION will start as shown in Table11.

17. COMPRESSOR PREHEATING

When the outdoor heat exchanger temperature is lower than temperature and the heating operation has
been stopped for 30 minutes, power is applied to the compressor and the compressor is heated.
(By heating the compressor, warm air is quickly discharged when operation is started.)
When operation was started, and when the outdoor temperature rises to temperature or greater, preheating
is ended.
(Table 13 : Preheating Operation / Release Temperature)
ASYA07/09/12/14/18LCC
ASYA09/12LDC
18. COIL DRY OR AIR CLEAN OPERATION CONTROL
(1). COIL DRY OPERATION CONTROL
The coil-dry operation functions by pressing COIL DRY button on the remote controller.
The coil-dry operation is consisted of 3 cycles of [Fan operation 3 minutes / Heating operation
2 minutes], and Fan operates for 3 minutes at last before ending the air conditioner operation.
(It takes 18 minutes to complete the coil-dry operation.)
(2). AIR CLEAN OPERATION CONTROL (ASYB09/12LDC model only)
The coil-dry operation functions by pressing AIR CLEAN button on the remote controller.
It continues from COIL DRY operation, it turns on electricity to AIR CLEAN UNIT, sterilization is
performed for 15 minutes.
Indoor unit fan motor operation under AIR CLEAN operation : The cycle of 480rpm Fixation
5 sec ON /1 min OFF is repeated.
(It takes 33 minutes to complete the AIR CLEANING operation.)
(Table 14 : COIL-DRY or AIR-CLEAN Operating Functions)
ASYA07/09/12LCC
ASYB09/12LDC
ASYA14/18LCC
Manual auto operation
Auto changeover
Auto
Continuous
(No timer setting available)
24°C
Standard
OFF
Temperature
Temperature
5°C
5°C
Indoor Fan Speed
900rpm
-
900rpm
480rpm
900rpm
-
Cooling
Hi
Room Temp is not controlled
Horizontal
OFF
7°C
7°C
Louver
Compressor
Frequency
Position
36Hz
36Hz
24Hz
05-13
Forced cooling operation
-
Main Unit
Indication
COIL-DRY or
AIR-CLEAN indication : ON
Other indication : OFF