R E F R I G E R A N T S Y S T E M D I A G R A M
Models : ASYA07LCC / AOYR07LCC
ASYA09LCC / AOYR09LCC
3-Way
valve
Muffler
4-Way valve
Cooling
Heating
Refrigerant pipe diameter
Liquid : 1/4" (6.35 mm)
Gas : 3/8" (9.52 mm)
Heat exchanger
( INDOOR )
Heat exchanger
( OUTDOOR )
03-01
2-Way
valve
Strainer
Expansion valve
Strainer