8. COMPRESSOR CONTROL

(1). OPEARTION FREQUENCY RANGE
The operation frequency of the compressor is different based on the operation mode as
shown in the table 10.
(Table 10 : Compressor Operation Frequency Range)
07/09LCC, 09LDC
12LCC, 12LDC
14LCC, 18LCC
(2). OPEARTION FREQUENCY CONTROL AT START UP
The compressor frequency soon after the start-up is controlled as shown in the figure 10.
(Fig.10 : Compressor Control at Start-up)
Frequency
Frequency
Frequency
Frequency
Frequency
Frequency
(Frequency)
ASYA07/09LCC
ASYA12LCC
ASYB09/12LDC
ASYA14/18LCC
(Time)
ASYA07/09LCC
ASYA12LCC
ASYB09/12LDC
ASYA14/18LCC
Cooling
Min
Max
18Hz
80Hz
18Hz
96Hz
18Hz
90Hz
Time
Time
Frequency
Frequency
56Hz
74Hz
56Hz
64Hz
56Hz
74Hz
40Hz
59Hz
Time
Time
80sec
60sec
80sec
30sec
80sec
60sec
60sec
40sec
Heating
Min
Max
18Hz
130Hz
18Hz
130Hz
18Hz
119Hz
Time
Time
Frequency
Frequency
87Hz
97Hz
74Hz
87Hz
87Hz
97Hz
72Hz
80Hz
Time
Time
60sec
180sec
30sec
30sec
60sec
180sec
40sec
60sec
05-09
Dry
33Hz
33Hz
24Hz
Time
Time
Frequency
Frequency
108Hz
119Hz
108Hz
120Hz
108Hz
119Hz
101Hz
110Hz
Time
Time
60sec
50sec
60sec
150sec
60sec
60sec
60sec
60sec