Troubleshooting - LG TD-C70070E Service Manual

Condensing dryer
Hide thumbs Also See for TD-C70070E:
Table of Contents

Advertisement

TROUBLESHOOTING

9
1. This TEST should be used for Factory test/Service test. Do not use this DIAGNOSTIC TEST other than specified.
2. Activating the Heater manually with Door open may trp the Thermostat attached to the Heater, therefore do not
activate it manually, (Do not press the door switch to operate the heater while the door is open)
Activating the diagnostic test mode
1. Unit must be in Standby (unit plugged in, display off)
2. Press " POWER" while pressing "Buzzer off" and "Wrinkle care" simultaneously.
No. of Button
pressing
None
1 time
2 times
3 times
4 times
5 times
6 times
7 times
Data Display
-Tested under normal operation mode.
「 Low Temp. 」 and 「 Time Down 」 button as follows.
- Press the
No. of Button pressing
1 time
2 times
3 times
Checkpoints
Check LED lamps
Motor run clockwise
Humidity data
Motor run clockwise
Humidity data
Motor run clockwire
Heat 1750W On
Motor run clockwise
Heat 1750W on, Heat 750W On
Motor On
Motor run counterclock wise
End
None
Temp sensed by low temp thermistor (located under door)
Temp sensed by High temp thermistor (located in base)
Moisture Pulse count(normal:1 ~ Increase)
Moisture Pulse Width time(100ms)
(normal:1 ~ Increase)
Temp sensed by low temp
thermistor(located under door)
Temp sensed by High temp
thermistor(located in base)
Display
18
Display

Hide quick links: