Component Testing Tips - LG TD-C70070E Service Manual

Condensing dryer
Hide thumbs Also See for TD-C70070E:
Table of Contents

Advertisement

COMPONENT TESTING TIPS

7
Component
1. Thermostat
(Manual type)
2. Thermistor
(Low temperature )
3. Heater,
Thermistor
Thermistor
4. Motor
6. Pump
Test procedure
Measure resistance of
Terminal to terminal
1) Open at 170°C (-10/+5°C)
Measure resistance of
terminal to terminal
Measure resistance of
Terminal to terminal
Measure resistance of
therminal to terminal
Measure resistance of
Terminal to terminal
Measure resistance of
Terminal to terminal
Check result
Measure resistance by pressing
button When resistance becomes ∞
Resistance value < 5Ω
Resistance value :
10KΩ 5% (at 25°C)
Resistance value :
Yellow/White : 28.96 1Ω
Blue/White : 56.29 2Ω
Resistance value :
200KΩ 5% (at 25°C)
Resistance value :
White/Blue : 24.8 2.5Ω
Blue/Red : 21.5 2.0Ω
Resistance value :
205±10Ω
15
Remark
Safety
Thermostat
Cover, Front
Heater

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents