Fujitsu SK-96390-100PMC User Manual page 17

Mb96300 series
Table of Contents

Advertisement

Jumper
JP4
(UART RESET)
JP7
(Reset imm./delayed)
JP24
(RST MCU)
JP35
(DTR / DTRx)
By default, the external reset is enabled and set to immediate reset while the reset by UART
is disabled.
Note:
While a reset signal is asserted the red Reset-LED D14 is lit.
During normal operation, this LED should be off!
If JP35 (DTR/DTRx) is set, the UART RESET jumper (JP4) and the according DTR/RTS
(JP3 and JP5) jumper have to be set, too.
If the reset LED is steadily on, check the power supply input voltage and the settings for the
reset-generation by UART.
© Fujitsu Microelectronics Europe GmbH
SK-96390-100PMC User Guide
Chapter 2 Jumpers and Switches
Setting
Description
1-2
X3 (UART0) is used to generate Reset
2-3
X5 (UART1) is used to generate Reset
Open
No UART is used to generate Reset
1-2
Reset is applied immediately when SW6 is pressed
2-3
Reset is applied when SW6 is pressed > 2sec
Closed
External reset generation is active
Open
No external reset generation
1-2
No polarity inversion for the DTR/RTS signal
2-3
Polarity inversion for the DTR/RTS signal
Open
No UART is used to generate Reset
Table 2-4: Reset Connection