6. Commisioning (functional checks)

6.1. Check pilot ignition

1. Push in and turn the control knob A from
setting. You will hear a tick meaning there is ignition. Hold the knob in and wait for a
few seconds while the air is purged.
2. Bring the knob back in the start position and turn the knob several times to the
(large flame) position. Check that the pilot has lit.
3. Continue to hold in the control knob for a further ten seconds to ensure that the pilot
flame is stable.
Release the knob. The pilot should remain alight.
4.

6.2 Functional burner check

1. Turn knob (B) to max. clockwise.
2. Turn the knob (A) more anticlockwise to the position
possible to light the main burner.
3. Turn knob B anticlockwise to max. The main burner should light. Check for gas
soundness at all joints with leak detection fluid!
4. Check the ignition of the main burner on low and high setting.
5.
Turn knob B clockwise till
6.
Turn the knob A to
anticlockwise to the
. The main burner is off.
. The pilot should go out.
UK/IRL
(small flame)
(large flame). Now it is
>
>
>
>
33