Table of Contents

Advertisement

XL-35/35C
7. Key input diagnosis Test Mode (TEST 6)
When the test mode is set, the following indication appears.
This test mode is intended to check whether all the main unit buttons can be detected. Accordingly, in this test mode checking as to
whether the "POWER ON/STAND-BY" button was pressed after all the buttons shown below were pressed is performed. If the result
is OK, OK is indicated. Even any one of keys was not pressed, an error is indicated. In case of OK termination or error termination
exit from this mode occurs when the "POWER ON/STAND-BY" button is pressed next time, and the standby mode is set.
1. In case of "MEMORY/SET" + "PLAY"+ "POWER ON/STAND-BY"
Since SURROUND and RDS are not provided, the following 9 buttons are detected as all buttons.
PLAY, POWER ON/STAND-BY, BAND, BASS/TREBLE, FUNCTION, MEMORY/SET, REC PAUSE, REW, FF, STOP.
The OK/NG indication of test result is as follows.
PU-IN SW detection error
Error content ............ The detection SW cannot detect ON
after a fixed period of time even if the
microcomputer controls the CD pickup
to return to the innermost position.
Probable cause ........ Defective or poorly connected PU-IN
SW or slide motor.
Action ....................... Solve the problem and turn on the power
again.
CD read error
Error content ........... Disc data cannot be read properly or
even if it can be read, the disc is not a
playable one.
Probable cause ....... The disc is loaded upside down, not CD-
DA, scratches, stains, etc.
Action ...................... Open the CD lid, then reload the disc
correctly. Remove the scratches or stains
on the disc.
NO DISC
Error content ........... Focusing is impossible.
Probable cause ....... The disc is loaded upside down, not CD-
DA, scratches, stains, etc.
Action ...................... Open the CD lid, then reload the disc
correctly. Remove the scratches or stains
on the disc.

ERROR LIST

Tape mechanism error 1
Error content ........... The detection SW "CAM-SW" cannot
Probable cause ....... Mechanism is in operation when this
Action ...................... Solve the problem and turn on the power
Tape mechanism error 2
Error content ........... Initialization cannot be completed when
Probable cause ....... Mechanism is in operation when this
Action ...................... Solve the problem and turn on the power
– 12 –
detect ON (mechanism in operation) even
if the motor and solenoid are controlled
to play back, fast forward, rewind, or
record the tape.
message appears: Defective or poorly
connected CAM-SW. Mechanism stops:
Defective or poorly connected motor or
solenoid.
again.
the microcomputer controls the motor
and solenoid to initialize the tape
mechanism (to set the mechanism to the
stop mode). The detection SW "CAM-
SW" cannot detect OFF While the
mechanism is in operation.
message appears: Defective or poorly
connected CAM-SW. Mechanism stops:
Defective or poorly connected motor or
solenoid.
again.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xl-35c

Table of Contents