VENT VALVE

FIG. 15-1 VENT VALVE - MyCafé AP
Location:
The vent valve is located inside the back access panel.
Function:
The vent valve closes (activates) only during hot water
dispense to pressurize tank.
Test Procedures:
1. With a voltmeter, check voltage across the termi-
nals of the vent valve. Activate valve in the "TEST
OUTPUTS" program mode. The indication must
be 12 vdc.
2. Coil resistance should be 28.8 ±10%.
Removal and Replacement:
1. Disconnect the brewer from the power source.
2. Disconnect the connectors from solenoid.
3. Cut cable tie(s) securing solenoid.
4. Disconnect hose from solenoid.
5. Install in reverse order.
FIG. 15-2 VENT VALVE - AutoPod
Page 15