To route the rear power cord, do the following:
1. Connect the plug to the Bulk Power Assembly (BPA), and ensure that the dots are aligned on the plug
and receptacle.
2. Secure the power cord in the channel with the brackets from top to bottom.
3. Remove the lower panel of the frame, and route the cord through the channel under the frame.
4. Route the rear power cord underneath the frame to the back floor tile hole. For more information about
floor cutouts, refer to the Site and Hardware Planning Information, order number SA38-0508.
5. Replace the lower panel of the frame.

Step 10. Verify the Hardware Management Console (HMC) Installation

Verify that the HMC is installed, then connect the HMC serial cable to serial port HMC1 on the primary I/O
book. For two HMCs, connect the redundant HMC into serial port HMC2 on the primary I/O book. The
following illustration shows the location of the serial ports on the rear of the HMC and the HMC connectors
located on the primary I/O book.
1
Primary Rack
2
Primary I/O Book
3
Power Plug to External Power Source (wall
plug)
16
Eserver pSeries 670 Installation Guide
4
Primary HMC Connected to serial port HMC1*
in Primary I/O Book
5
Optional Second HMC Connected to serial port
HMC2* in Primary I/O Book
* May be labeled HSC1 and HSC2