Definition of a new Alphanumeric String assigned to a control

Byte (Hexadecimal)
F0
00
20
4F
00
00
09
or 19
GG
NN
32 nibbles
CS
F7
Definition of an alphanumeric string assigned to a BitStream Control
The 32 nibbles to include on the above sysex are coding all string (2 nibbles per character, MSB first)

Definition of the Acknowledge SYSEX sent by BitStream

The following table illustrates the SYSEX returned by BitStream when a control configuration has been
sent with an acknowledge request (Codes 0x12 and 0x19)
Byte (Hexadecimal)
GG
NN
ACK
Acknowledge Sysex sent by BitStream in response of a configuration with acknowledge request
(Message recognized by BitStream Pro)
F0
00
20
4F
00
00
02
TT
F7
(Message transmitted by BitStream Pro)
Rev 3.1 - Page
Description
Start of SYSEX
Waveidea ID
MIDI Controller ID
BitStream Pro ID
BitStream Pro ID
Reserved
Alphanumeric string configuration request
Alphanumeric string configuration request with
acknowledge from BitStream
Group (00:A 01:B 02:C)
Control to configure
0x00 - 0x27 potentiometers (0 - 39)
0x28 - 0x2F Switches (40 - 47)
0x30 LFO (48)
16 bytes (32 nibbles) to define the
new Alphanumeric string
Checksum
Sum of the 32 preceding Nibbles
modulo 128
End Of SYSEX
Description
Start of SYSEX
Waveidea ID
MIDI Controller ID
BitStream Pro ID
BitStream Pro ID
Reserved
Acknowledge
Acknowledge on :
TT = 00 : MIDI string
TT = 01 : Alphanumeric String
Group (00:A 01:B 02:C)
Acknowledge on :
0x00 - 0x27 potentiometers (0 - 39)
0x28 - 0x2F Switches (40 - 47)
0x30 LFO (48)
00 : Successful Configuration
01 : Configuration Error
End Of SYSEX