SECTION 4

MECHANICAL ADJUSTMENTS

Precaution
1.
Clean the following parts with a denatured alcohol-moistened
swab:
record/playback heads
erase head
capstan
2.
Demagnetize the record/playback head with a head
demagnetizer.
3.
Do not use a magnetized screwdriver for the adjustments.
4.
After the adjustments, apply suitable locking compound to the
parts adjusted.
5.
The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
Torque Measurement
Torque meter
Mode
FWD
CQ-102C
FWD
CQ-102C
back tension
REV
CQ-102RC
REV
CQ-102RC
back tension
FF/REW
CQ-201B
FWD tension
CQ-403A
REV tension
CQ-403R
pinch rollers
rubber belts
idlers
Meter reading
31 to 71 g • cm
(0.43 – 0.98 oz • inch)
2 to 6 g • cm
(0.02 – 0.08 oz • inch)
31 to 71 g • cm
(0.43 – 0.98 oz • inch)
2 to 6 g • cm
(0.02 – 0.08 oz • inch)
71 to 143 g • cm
(0.98 – 1.99 oz • inch)
100 g or more
(3.53 oz or more)
100 g or more
(3.53 oz or more)
SECTION 5

ELECTRICAL ADJUSTMENTS

Read before adjustments
To adjust the unit, operate the unit by itself using the conduction jig
(PFJ-1).
For details on switching functions and fast forwarding the unit, etc.
when operating it by itself, refer to "Connection and Operations of
the Unit by Itself" on page 5 of Servicing Notes.
• Turning on the power
When operating the unit by itself:
1.
After turning ON the power of the conduction tool (PFJ-1),
press the π (TAPE A) button, π (TAPE B) button, and ·
(TAPE B) button together in this order.
Inputting/outputting audio signals:
Use the jack of the power supply jig (PFJ-1).
PFJ-1
DECK SECTION
0 dB=0.775V
1.
Demagnetize the record/playback head with a head
demagnetizer.
2.
Do not use a magnetized screwdriver for the adjustments.
3.
After the adjustments, apply suitable locking compound to the
parts adjusted.
4.
The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
5.
The adjustments should be performed in the order given in this
service manual. (As a general rule, playback circuit adjustment
should be completed before performing recording circuit
adjustment.)
6.
The adjustments should be performed for both L-CH and R-
CH.
Signal
Tape
P-4-A100
10 kHz, –10 dB
WS-48B
3 kHz, 0 dB
P-4-L300
315 Hz, 0 dB
7.
Switches and controls should be set as follows unless otherwise
specified.
Record/Playback Head Azimuth Adjustment
(Deck A, Deck B)
Note: Perform this adjustments for both decks.
Procedure:
1.
Mode : Playback
test tape
P-4-A100
(10kHz, -10dB)
set
Output point
Input point
Used for
Azimuth Adjustment
Tape Speed Adjustment
Level Adjustment
level meter
PFJ-1
output point
11

Advertisement