20. Clock Adjustment
Requirement
*
Measuring instrument: Frequency counter
Test point: CLOCK, GND
Adjustment point: L951
(1) While pressing and holding down the POWER button and the UP button, insert the AC plug.
(2) Adjust L951 so that the frequency counter indicates 72.743 ± 0.073 Hz.
PA TTERN SIDE
PA RTS SIDE
L951
KSCAN
GND
-38-
FREQUENCY CO UNTER
Hz
CLOCK
GND