Electrical Adjustment - Aiwa XR-X77 Service Manual

Hide thumbs Also See for XR-X77:
Table of Contents

Advertisement

ELECTRICAL ADJUSTMENT -1/6

TUNER ADJUSTMENT
1. Clock Check
Requirements
Measuring equipment: Frequency counter
Test point: TP1 (CLOCK), GND
1) Adjust the reception frequency of the main unit to 1710KHz.
2) Check that the test point frequency is 2160 0.045KHz.
2. VT Adjustment (LW)
Requirement
Measuring equipment: Digital multi-meter
Test point: TP4 (R962), GND
Adjustment point: L942
1) Adjust the reception frequency of the main unit to 144KHz.
2) Adjust L942 until the test point voltage (VT) is 1.3V 0.05V.
3. VT Check (MW)
Requirement
Measuring equipment: Digital multi-meter
Test point: TP4 (R962), GND
1) Adjust the reception frequency of the main unit to 531KHz.
2) Check that the test point (VT) voltage is about 0.5V.
3) Adjust the reception frequency of the main unit to 1602KHz.
4) Check that the test point (VT) voltage is below 8.0V.
4. VT Adjustment (FM)
Requirement
Measuring equipment: Digital multi-meter
Test point: TP4 (R962), GND
Adjustment point: L907
1) Adjust the reception frequency of the main unit to 108.0MHz.
2) Adjust L907 until the test point voltage (VT) is 7.0V 0.1V.
3) Adjust the reception frequency of the main unit to 87.5MHz.
4) Check that the test point (VT) voltage is about 0.5V.
-38-

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xr-x77 k(s)Xr-x77 ez(s)

Table of Contents