SERVICE (cont.)

HALF BATCH SWITCH (Optional)

FIG. 28 HALF BATCH SWITCH
Location:
The HALF BATCH switch is located in the front of
the hood, above and to the far left of the brew funnel.
Test Procedure:
1. Disconnect the brewer from the power source.
2. With an ohmmeter, check for continuity between
the two terminals of the switch.
If continuity is present as described, the switch is
operating properly.
If continuity is not present as described, replace the
switch.
Removal and Replacement:
1. Remove the wires from the switch terminals.
2. Compress the clips inside the hood and gently
push the switch through the opening.
3. Push the new switch into the opening and spread
the clips to hold the switch captive in the hood.
4. Refer to FIG. 29 when reconnecting the wires.
FIG.29 HALF BATCH SWITCH TERMINALS
P1959.60