Advertisement

2. Set the remote control selector switch with the
remote control
[B] is indicated on the liquid crystal display when
setting remote control selector switch to B. [A] is
not indicated on the display even if the selector
switch is set to A.
1) Load the remote control with the batteries.
2) Press the [CHECK] button using something with
sharp point. (The preset temperature on the remote
control changes to [00].)
3) Press the [MODE] button while pressing the
[CHECK] button, [B] is indicted at the right of the
present temperature display.
• To reset the switch to the [A] setting, press the
[MODE] button again while pressing the [CHECK]
button.
MODE
TEMP.
FAN
AUTO
AUTO
COOL
QUIET
DRY
AUTO FAN
TEMP.
START/STOP
SWING
FIX
FAN
MODE
ECO
RST CHK
TIMER
ON
OFF
SET
CLR
Fig. 8-6-2
3. Confirm that the indoor unit can operate with
the new setting.

8-7. Others

8-7-1. Gas leak test
• Check the flare nut connections, valve stem cap
8-7-2. Test operation
To switch the TEST RUN (COOL) mode, press
TEMPORARY button for 10 sec.
(The beeper will make a short beep.)
B
[MODE] button
[CHECK] button
8-7-3. Auto restart setting
This product is designed so that, after a power failure,
it can restart automatically in the same operating mode
as before the power failure.
<How to set the auto restart>
• Press and hold the TEMPORARY button for about
• To cancel the Auto Restart, follow the steps
– 44 –
Valve stem cap
connection
Service cap
connection
Fig. 8-7-1
connections and service port cap connections for
gas leak with a leak detector or soap water.
TEMPORARY button
Fig. 8-7-2
Information
The product was shipped with Auto Restart function
in the off position. Turn it on as required.
3 seconds. After 3 seconds, the electronic beeper
makes three short beeps to tell you the Auto
Restart has been selected.
described in the section Auto Restart Function of
the Owner's Manual.
FILE NO. SVM-04017
Valve cover