Ras-10Uk-Es3 / Ras-10Ua-Es3 - Toshiba RAS-13UKH-ES3 Service Manual

Table of Contents

Advertisement

5-4. RAS-10UK-ES3 / RAS-10UA-ES3

Cooling
0.39 m
(Connecting pipe)
∅9.52
O.D.:9.52 mm
P
Packed valve
(∅9.52)
Cooling
Cooling Compressor
Cooling
50Hz
Standard
Cooling
Overload
Low temperature
Note
• Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
Indoor unit
Evaporator
Cross flow fan
PA108X1T-4FZ1
Condenser
Propeller fan
Outdoor unit
Standard
Surface temp. of heat
pressure P
exchanger interchanging
(MPaG)
pipe T1 (°C)
0.95
1.15
0.85
– 17 –
T1
Packed valve
(∅6.35)
Capillary tube
∅1.5 x 1100l
Refrigerant
R410a : 0.65 kg.
Mark (
) means check points of Gas Leak.
Fan speed
(indoor)
11.0
High
15.0
High
5.0
Low
FILE NO. SVM-04017
0.49 m
(Connecting pipe)
∅6.35
O.D.:6.35 mm
Ambient temp.
conditions DB/WB
(°C)
Indoor
Outdoor
27/19
35/24
32/23
43/26
21/15
21/15