Troubleshooting - Honeywell KS20S KaltecSoft Evolution Operation Manual

Hide thumbs Also See for KS20S KaltecSoft Evolution:
Table of Contents

Advertisement

Available languages

Available languages

11. Troubleshooting

Problem
Error Code 101
Unable to recognize start of regenera-
tion
Error Code 102
Unexpected stall
Error Code 103
Motor ran too long, timed out trying to
reach home position
Error Code 104
Motor ran too long, timed out trying to
reach home position
IF OTHER ERROR CODES DISPLAY
CONTACT THE AUTHORIZED
INSTALLER
Control valve stalled in regeneration Motor not operating
Control valve does not regenerate
automatically when Regeneration
button
is depressed and held
Water softener delivers hard water
Time of day flashes on and off.
MU5H-1419GE23 R0815
Cause
Not reading piston position
Incorrect Assembly
Mechanical binding
High drive forces on piston
Control valve piston not in home position Push
Motor not inserted fully to engage pinion,
motor wires broken or disconnected, motor
failure
Drive gear label dirty or damaged, missing
or broken gear
Drive bracket incorrectly aligned to back
plate
PC Board is damaged or defective
PC board incorrectly aligned to drive
bracket
No electric power at outlet
Defective transformer
Defective PC board
Broken drive gear or drive cap assembly
Broken piston retainer
Broken main or regenerant piston
Transformer unplugged
No electric power at outlet
Broken drive gear or drive cap assembly
Defective PC Board
Bypass valve in Bypass position
Defective meter
Restricted/stalled meter turbine
Set-up error
No salt or low salt level in brine tank
Excessive water usage
Insussicient brine level in brine tank
Raw water hardness fluctuation
Defective PC board
Battery back up maintains time of day up to
2 years in event of power outage and
battery is discharged. Time of day flashes
when battery is discharged
19
Remedy
Resynchronize software with piston position.
Push
and
for 3 seconds
Disassemble drive bracket,verify wires are in
guides & reassemble
Check Piston and spacer stack assembly for
foreign matter
Loosen drive cap gear ¼ turn or replace.
Address high drive forces.
and
for 3 seconds
Check motor and wiring. Replace motor if
necessary
Replace or clean drive gear
Reseat drive bracket
Replace PC board
Ensure PC board is correctly snapped on to
drive bracket
Replace motor
Repair outlet or use working outlet
Replace transformer
Replace PC Board
Replace drive gear or drive cap assembly
Replace drive cap assembly
Replace main or regenerant piston
Connect transformer
Repair outlet or use working outlet
Replace drive gear or drive cap assembly
Replace PC Board
Put bypass valve in position service
Test meter and clean or replace meter
Remove meter and check for rotation or
foreign matter
Check control valve set up procedure
Add salt to brine tank and maintain salt level
above water level
Check capacity settings
Check brine refill setting and refill flow
restrictor for blockage
Test raw water hardness and adjust settings
to highest known hardness
CONTACT THE AUTHORIZED INSTALLER
Reset time of day and replace battery on PC
Board (Lithium coin type Battery 2032)
Honeywell GmbH

Hide quick links: