System Parameters - Honeywell KS20S KaltecSoft Evolution Operation Manual

Hide thumbs Also See for KS20S KaltecSoft Evolution:
Table of Contents

Advertisement

Available languages

Available languages

11. Push
or
to change between the reserve
types:
• AUTO (default): capacity and reserve are automatically
calculated.
• OFF: reserve calculator is not active.
8.5.9. Regeneration start time
1. Push
to go to the next parameter.
The display shows DELAYED.
2. Push
or
to select the regeneration start
time between:
• DELAYED: regeneration on a specific time
• IMMEDIATE: immediate regeneration when volume
is at 0
• DELAY+IMMEDIATE (default): delayed regeneration
with override on 0 volume
8.5.10.Service alarm
1. Push
to go to the next parameter.
The display shows SERVICE ALARM.
You can set the service alarm basing on time, volume or both.
2. Push
or
to set the unit:
• TIME: based on time
• m³:
based on volume
• BOTH: based on time and volume
• OFF: no service alarm defined
Example:
Service alarm every 3 months
If set up service alarm is based on time each push increases
or decreases the time by 3 months.
The display shows SERVICE ALARM if setting is based on
volume or both.
Example: Service alarm every 500 m³
Push
to go to the next parameter.
Honeywell GmbH
8.5.11.Scheduled service
The display shows SCHEDULED SERVICE.


For more information on scheduled service go to paragraph
10. Maintenance.
3. Push
to exit the settings.
The display shows TIME OF DAY or another general para-
meter (see 8.1. General parameters).

8.6. System parameters

Push and hold for 3 seconds both buttons
and repeat this for further 3 seconds until the display
shows DISPLAY and the system language flashes.

8.6.1. Language settings
1. Push
or
2. Push
to go to the next parameter.
Valve parameters
8.6.2.
The display shows VALVE TYPE and the type number
flashes.
Example:
25 mm is set as default.
8.6.3. Valve body and hardness unit
1. Push
or
2. Push
to go to the next parameter.
The display shows HARDNESS UNITS.
3. Push
or
• ppm: parts per million
• °dH:
German degree
• °fH:
French degree, default
• NA:
no hardness setting
4. Push
to go to the next parameter.
14

and
to change the language.
to set up the size.

to set the hardness unit:
MU5H-1419GE23 R0815