Air Cleaner - NC SW6 Maintenance Instructions Manual

Site dumper
Table of Contents

Advertisement

AIR CLEANER SERVICING
The air cleaner needs serviced when the red line on the
visual indicator line (A) reads 75 kpa, the box on the
indicator labelled service when red (B) will also be
filled. This should be one of the daily machine checks.
Maximum protection for the engine against dust is
possible only if the air cleaner is serviced correctly. The
only way to determine if an air cleaner requires cleaning
or replacing is to check.
Never run the engine with the filtration elements
removed from the air cleaner.
Squeeze the solids ejector (C) to remove material from
the pre cleaner drop tube.
To service the air cleaner, first clean its surrounding
area and then release the 2 retention latches (D)
holding on the pre-cleaner end (E).
Remove the primary filter (F) by pulling it out from
the main filter body, this will expose the inner safety
filter (G). Either renew or clean these elements. Clean
by using compressed air to carefully blow dust out of
the filter.
Reassemble by reversing the above procedures .