PRE-INSTALLATION INFORMATION

INSTALLING ABOVE 2000 FEET

In the USA, the appliance must be derated 4% for every 1,000 ft above 2,000 ft elevations.
In Canada, these appliances are certified for altitudes of 0 – 2000 ft, and must be de-rated by 10 percent for installations
between 2000 and 4,500 ft. (derate an additional 4% for every 1,000 ft. above 4,500 ft. elevations).
ORIFICE SIZES, PRESSURES AND BTUs
NATURAL GAS
Manifold Press: (W.C.)
Maximum Supply Pressure
Minimum Supply Pressure
Model Number
Max. Btu/hr Input
Min. Btu/hr Input
Orifice sizes (as shipped)
The IDV490NVC, IDV490PVC, IDV380NVC, and 380IDVPVC are equipped with a variable output gas control.
NOTE: IDV490NVC, IDV490PVC, IDV380NVC, and IDV380PVCinserts work without any electrical supply.
Blower must be attached to 110/120 VAC.
INSTALLATION PLANNING
Plan for the installation of your insert. This includes determining the size of fireplace in which unit is to be installed, length of
venting to be used, and finishing details, and whether any optional accessories (i.e. wall switch, or remote control) are desired.
Consult your local building code agency to ensure compliance with local codes, including permits and inspections.
6
PROPANE GAS
3.5"
Manifold Press: (W.C.)
10.5"
Maximum Supply Pressure
4.5"
Minimum Supply Pressure
IDV490NVC
NATURAL
40,000
26,500
#30
10"
13"
11"
IDV490PVC
IDV380NVC
PROPANE
NATURAL
37,500
30,500
29,000
20,500
#50
#35
IDV380PVC
PROPANE
28,000
22,000
#53
57D0016