7.2 Menu structure

Parameter change: The menu is accessed using the "Menu"
key. In this menu, changes can be made to parameters. The de-
sired menu item is selected with the arrow keys "UP" "DOWN".
The submenu is accessed using the "OK" key.
Menu block
Menu item
Settings
System time
System date
Language
Sound
Backlight
Warm water
Set point temp.
Setback tempera
Hysteresis
(only visible for devices with additional heat exchanger and Sol selection under the menu block 2nd heat generator
Solar
Heater sel.
Switch on differenc
Switch off differenc
Max. storage tem
Max. collector tem
Time programs
Therm. disinfection
www.dimplex.de
Parameter
Value
00:00
DD:MM:YYYY
German
English
On
Off
0 % ... 50 % ...100 %
25 °C ... 45 °C ... 85 °C
15 °C ... 25 °C ... 40 °C
2 K ... 3 K ... 10 K
Off
2nd
Sol
6 K ... 8 K ... 10 K
2 K ... 4 K ... 6 K
60 °C ... 65 °C ... 85 °C
125 °C ... 130 °C ... 135 °C Sets the maximum permissible temperature on the collector
Start time
00:00 ... 23:59
Days
Mo ... Su
Sollwert
60 °C ... 65 °C ... 85 °C
451905.66.02 · FD 9506
In this submenu, the parameter that is to be changed can be se-
lected (also using the arrow keys). The "OK" key is used to se-
lect the marked value, which can then be changed via the arrow
keys. The entry is completed by pressing the "OK" key again.
Description
Time setting (24 hour time display)
Date setting (Day:Month:Year)
Language selection
Setting key tone on / off
Setting display backlight
Sets the desired domestic hot water set temperature
Sets the minimum hot water temperature, which should also not be
undershot for the duration of a programmed shut-off time.
Sets the switching hysteresis
Choice of additional heat source
Off: (no add. heat source)
2nd: 2nd heat generator, e.g. oil, gas or wood boiler
Sol: Thermal solar energy system
Sets the temperature difference between the collector and cylinder
temperature at which the solar pump should be switched on
Sets the temperature difference between the collector and cylinder
temperature at which the solar pump should be switched off
Sets the maximum cylinder temperature that is permissible when solar
gain is available
Sets the start time for thermal disinfection (24 hour time display)
Sets the day on which thermal disinfection should be activated
Sets the set temperature for thermal disinfection.
DHW 300D - DHW 300D+
EN-9