Installation; Troubleshooting - Teka TL-62 Instruction Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 15
To fix the extractor to the kitchen unit
the pattern on page 19 is used.
The lower part of the extractor must be
located at a minimum height of 60 cm
above the hob for electric cookers and
65 cm for gas cookers. If the instruc-
tions of a gas cooker indicate a greater
distance these must be observed.
The extractor must be connected to a
wall socket with an effective earth.
When the extractor is working at the
same time as other non-electrical cook-
ing equipment, the outlet air pressure
must not exceed 4 Pa (4 x 10-5 bar).
To achieve optimum performance the
length of the outlet hose should not
exceed 4 meters, or include more than
two 90º angles (elbows)
Although venting to the outside is rec-
ommended, activated carbon filters may
be used, which allow the gas to be
returned to the kitchen through the out-
let pipe.
If you wish to exchange the front for one
matching the kitchen units, follow the
following instructions:
- Withdraw the movable group.
- Remove the screws (T) that suppor t
the front
- Install the new front fixing it with the
same screws that held the old one.
Defect
The extractor
does not work
The extractor does not
blow enough or vibrates
The lamps do not light
18

Installation

The cable is not connected
No current is reaching the plug
Filter saturated with grease
Inadequate air conduit
Ajuste Prof. Mueble
If something does not work
Before seeking technical assistance car-
ry out the following checks first.
Possible cause
Outlet obstructed
Lamp broken
Lamp loose
T
T
T
Solution
Connect the mains cable
Revise/repair the
electricity circuit
Clean or substitute filter
Eliminate obstructions
Contact the installer and follow
instructions of this manual
Exchange the bulb
Tighten bulb

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tl-92Cnl 1000Cnl 2000

Table of Contents