(FTNE35)

In sites with poor drainage,
use block bases for outdoor
unit. Adjust foot height until
the unit is leveled.
Otherwise, water leakage
or pooling of water may
occur.
* Appearance of the outdoor unit
may differ from some models.
Where there is a danger of the unit
falling, use foot bolts, or wires.
Unit: mm
Model
Max. piping allowable length
Min. piping allowable length
Max. piping allowable height
Additional refrigerant required
for refrigerant pipe exceeding
10m in length.
Gas pipe
O.D. 12.7mm
Liquid pipe
O.D. 6.4mm
Be sure to add the proper amount of
additional refrigerant. Failure to do so
may result in reduced performance.
The suggested shortest pipe length is
3m, in order to avoid noise from the
outdoor unit and vibration.
(Mechanical noise and vibration may occur
depending on how the unit is installed and
the environment in which it is uesd.)
Stop valve cover
How to remove the stop
valve cover.
• Remove the screw on the
stop valve cover.
• Slide the cover downward
to remove it.
How to attach the stop
valve cover.
• Insert the upper part of the
stop valve cover into the
outdoor unit to install.
• Tighten the screws.
Allow space for piping
and electrical servicing.
RNE35
20m
2.5m
15m
20g/m
29