IBM eServer 380 xSeries User Reference Manual page 78

Hide thumbs Also See for eServer 380 xSeries:
Table of Contents

Advertisement

0131h
0132h
0135h
0136h
0137h
0140h
0150h
0170h
0180h
0184h
0190h
64
xSeries 380: User's Reference
Code
Parity failure at xxxxxxxxh
during pattern test. While
performing the pattern test
to the specified address,
AMIDiag received a parity
error.
Faulty memory chip on
SIMMM xxxx1. Reseat
Memory DIMMs 2. Replace
Memory Board.
ECC correctable error in
SIMM sockets xxxx/yyyy
ECC uncorrectable error in
SIMM sockets xxxx/yyyy
Error occurred on bank xxxx
interleave yyyy
Failure at address
xxxxxxxxh, bit position bbh.
A failure occurred at the
specified address.
Failure at xxxxxxxxh, bit
position bbh. A failure
occurred at the specified
address.
RAM Refresh is not working.
The system RAM refresh
signal is either not being
generated or the signal is
being generated
sporadically.
The pattern written at
address xxxxxxxxh was
qqqqh. The pattern read
back from that address was
pppph. The diagnostic
program wrote a pattern to
address xxxxxxxxh. When
reading it back, AMIDiag
read a different value from
that same address.
Data bus short found1
Test failed at address
xxxxxxxxh. An unknown
memory error occurred at
xxxxxxxxh.
Explanation
Call for service.
Action

Advertisement

Table of Contents