1-5 Assembly and Disassembly

1-5-1

Precautions for assembly and disassembly

(1) Precautions

Be sure to turn the power switch off and disconnect the power plug before starting disassembly.
When the fax kit is installed, be sure to disconnect the modular code before starting disassembly.
When handling PWBs (printed wiring boards), do not touch connectors with bare hands or damage the board.
Do not touch any PWB containing ICs with bare hands or any object prone to static charge.
Use only the specified parts to replace the fuser unit thermostat. Never substitute electric wires, as the machine may be
seriously damaged.
When removing the hook of the connector, be sure to release the hook.
Y107330-8