» Precautions in handling the LCD panels
1. Work in a clean room (with humidities below 50%).
2. Be sure to wear an anti-static armband.
3. Handle the panels on an electro-conductive mat.
4. Be careful not to fall, shake and shock the panels.
13. Remove the 3 lock screws from the LCD panel and detach the LCD panel.
14. Remove the reflection/polarization sheet, prism sheet, diffusion sheet and diffusion panel.
15. Detach the lamp holders (top)-A, (top)-B and (bottom) from the lamp unit assembly.
16. Detach the reflection sheets (top) and (bottom) from the back shield.
Reflection/Deflection Sheet
(PSHEPA101WJZZ)
Diffusion Sheet
(PSHEPA127WJZZ)
13
13
20" LCD Panel Unit
13
Lamp Holder (Bottom)
(LHLDZA213WJKZ)
Lamp Unit Ass'y
(CLMP-A024WJ01)
Lamp Holder (Top)-A
(LHLDZA211WJKZ)
Diffusion Plate
14
(PCOVUA014WJZZ)
Prism Sheet
(PSHEPA102WJZZ)
Back shield Ass'y
(CSLDMA251WJ01)
Reflection Sheet (Top)
(PSHEPA103WJZZ)
15
Lamp Clip
(LHLDZA214WJKZ)
Lamp Holder (Top)-B
(LHLDZA212WJKZ)
11
LC-20S2U-S
16
Reflection Sheet (Bottom)
(PSHEPA104WJZZ)