14)Lamp housing (See Fig. 15.)
Remove the three screws (S-7) shown in Fig. 15,
and detach the lamp housing from the bottom cover.
Remove the screws (S-15) shown in Fig. 15, and
detach the thermistor and thermistor plate.
Remove the screw (S-7) shown in Fig. 15, and
detach the ballast lock base.
With the lamp housing taken out, the 40 fan
assembly (DC) can be detached.
Note: Take note of the wiring for the 40 fan assembly,
which goes below the lamp housing.
40FAN(DC)
S-7
15)Power unit (See Fig. 16.)
Remove the two screws (S-7) shown in Fig. 16, and
detach the fan base from the cover.
Remove the screws (S-5 and S-10 one each) and
the two D/M spacers shown in Fig. 16, and detach
the power unit.
S-10
40FAN(L)
S-7
S-7
Fan Base
S-7
Lamp housing
S-15
Thermistor
Ass'y
Thermistor
Plate
S-15
Fig. 15
S-5
D/M Spacer
Power Unit
Fig. 16
16)Front and rear feet (See Fig. 17.)
As shown in Fig. 17, press the hook (1) first and
then the hook (2). Remove the front feet.
Turn the rear feet away out of place.
Remove the screw (S-7) shown in Fig. 17, and
detach the lamp limit switch.
S-7
Rear Foot
Front Foot
14
Lamp Limit
Switch
Fig. 17