1. Preparations and precautions
Tools required
1. Phillips screwdriver, Nos. 1 and 2
2. Phillips and bladed precision screwdrivers
3. Anti-static wrist band
4. Hexagonal wrench (opposite side: ___ mm)
Precautions for disassembly and reassembly
1. Before starting the procedure, unplug the power cable.
2. Some parts are still hot immediately after operation. Wait until they have cooled down.
3. Restore the components, screws and wires in their original positions.
4. Follow the important notes in handling the components and carrying out the job.
5. Be careful not to confuse the specific component parts for different models.
6. Do not tamper with the unit to ensure safety.

2.Disassembly and reassembly

1) Front panel (See Fig. 1 and Fig. 1-A.)
Remove the two screws (S-8) shown in Fig. 1.
Remove the front panel as shown in Fig. 1-A.
Note: Take care not to damage the IR cable.
2
1
Front Panel
DISASSEMBLY AND REASSEMBLY
S-8
Fig. 1
Fig. 1-A
2) Top cover (See Fig. 2.)
Remove the two louver screws (S-8) shown in Fig.
2.
Remove the top cover as shown in Fig. 2.
Note: Take care not to damage the speaker cable.
Louver
Screw
10
Top Cover
S-8
Louver
Screw
Fig. 2