Take off the protection hood and do the following:
1.Clean the openings and the burner sreen with a toothbrush;
2.Clean and inspect the electrode and thermocouple.if either is
corroded,have it changeed.Check that they are well attached
and if necessary tighten the screws;
3.Check that the spark is created by pressing the electric piezo
ignite button on the control panel.
4.Do not use thin objects to either clean or unblock the injector
Cleaning the Cooling System Flue
WARNING Carbon Monoxide can be hazardous to your health. Gas appliances may emit
excessive Carbon Monoxide if the refrigerator's burner, burner orifice, and the flue tube are
not regularly cleaned. To prevent Carbon Monoxide, the burner, burner orifice, and the
cooling system's flue tube must be cleaned at least once a year and after all prolonged
(seasonal) shut-down periods. Refer to the following cleaning procedures, or contact a
qualified installer, your dealer.
Before cleaning,Put a cloth on the burner to protect it from dirt;
1. Remove the refrigerator from its enclosure.
2. Remove the heat deflector cap from the flue.
3. Remove the spiral flue baffle from the flue tube.
4. Using a stiff brush or fine emery cloth, clean the spiral flue baffle of debris.
5. Clean the inside of the flue tube with a flue brush. Inspect burner after cleaning.
6. Re-install the spiral flue baffle. Insure the spiral flue baffle is securely in place. The spiral
flue baffle is required for efficient cooling while operating in the gas mode.
TROUBLE SHOOTING AND MAINTENANCE
If the refrigerator fails to work,Check the following points before calling a service
technician:
1. That the above installation and operating instructions have been followed.
2. The refrigerator is level.
3. If it is possible to start the refrigerator on any of the connected sources of energy.
4. If the refrigerator fails to work on gas, check:
That the gas bottle is not empty.
That all LP-gas valves are open.
If the refrigerator is not cold enough it may be because: