LP GAS CONNECTION

The refrigerator is designed for operation on LP gas, the pressure of which must be
30 mbar for Propane Check that this is stated on the dataplate.
The refrigerator is not designed for operation on town gas or natural gas.
CAUTION! CHECK THAT THE GAS SUPPLIED TO THE REFRIGERATOR IS AT THE PROPER
PRESSURE. SEE THE PRESSURE REGULATOR ON THE LP GAS CONTAINER.
The gas installation and servicing should only be carried out by an authorized,
qualified person and must conform to all relevant national and local regulations.
The gas supply pipe should be connected to the gas inlet of the gas control valve
by means of a suitable threaded coupling.
In making the connection to the refrigerator, a union gas cock of an approved
bottled-gas type must be incorporated in the supply line in a position which is
readily accessible to the user. For eventual servicing purposes, the union should be
on the outlet side of the cock and the pipework should be positioned so as not to
prevent the refrigerator from being readily withdrawn.
Never check gas leaks with an open flame. Use an approved leak-detection
solution.

OPERATION INSTRUCTIONS

Fig1
A
After initial installation, servicing, or changing gas cylinders etc., the gas pipes may
contain some air which should be allowed to escape by briefly turning on the
refrigerator. This will ensure that the flame lights immediately.
1. Make sure that all valves between the gas container and the refrigerator are
open.
2. Depress the safety device control (D) and hold it down while depressing the
Pulse ignition switch (B) .
3. Check the flame indicator (C) to see whether the flame is alight.
4. Keep the safety device control (D) depressed for a further 10-15 seconds.
5. Release the safety device control (D ) and again check to see that the flame is
alight.
To terminate gas operation, turn off the gas valve from the gas container.
B
C
D
E
A: Pulse ignition battery
B: Pulse ignition switch
C: Flame indicator
D: Safety valve