■ Lamp Replacement

■ Lamp Replacement
When the life of the projection lamp of this projector draws to
an end, the LAMP REPLACE indicator lights yellow. If this
indicator lights yellow, replace the lamp with a new one
promptly.
CAUTION
Allow a projector to cool, for at least 45 minutes before
you open the Lamp cover. The inside of the projector
can become very hot.
Follow these steps to replace the lamp.
1
Turn off the projector and disconnect the AC plug. Allow the
projector to cool for at least 45 minutes.
2
Turn over the projector. Loosen the screw with a screwdriver,
and remove the lamp cover.
3
Loosen 2 screws of the lamp with a screwdriver and pull out the
lamp by grasping the handle.
4
Replace the lamp with a new one and tighten the 2 screws back
into position. Make sure that the lamp is set properly. Replace
the lamp cover and tighten the screw.
5
Connect the AC power cord to the projector and turn on the
projector.
6
Reset the Lamp replace counter.
See "Lamp Replace Counter" on the next page .
ORDER REPLACEMENT LAMP
Replacement lamp can be ordered through your dealer. When ordering a projection lamp, give the following information
to the dealer.
Model No. of your projector
Replacement Lamp Type No.
■ Lamp Replacement Counter
Be sure to reset the lamp replace counter after the lamp is replaced. When the lamp replace counter is reset, the LAMP
REPLACE indicator stops lighting.
1
Turn the projector on, press the MENU button, and the On-
Screen Menu will appear. Select the Setting Menu with the
Point Up/Down button and press the Point Right button to
enter the sub-menu.
2
Select the Lamp counter reset item and then press the
SELECT button. The message "Lamp replace counter
Reset?" is displayed. Choose [Yes] and then press the
SELECT button.
3
Another confirmation dialog box appears and choose [Yes] to
reset the Lamp replace counter.
NOTE
● Do not reset the Lamp replace counter without implementation of lamp replacement. Be sure to reset the Lamp
replace counter only after replacing the lamp.
This indicator lights yellow
when the life of the projection
lamp draws to an end.
CAUTION
For continued safety, replace with a lamp of the same
type. Do not drop a lamp or touch a glass bulb! The
glass can shatter and may cause injury.
:
PLV-Z2
:
POA-LMP69
(Service Parts No. 610 309 7589)
Lamp counter reset
-4-
Top Control
Screw
Lamp Cover
Lamp
Screw
Handle