Axis 10-Pin Push-Pull System Connector (Sold Separately) - Axis P5635–E User Manual

Ptz dome network camera
Hide thumbs Also See for P5635–E:
Table of Contents

Advertisement

AXIS P5635–E PTZ Dome Network Camera
Technical Specifications
I/O connector - 6–pin terminal block. Use with external devices in combination with, for example, tampering alarms, motion
detection, event triggering, time lapse recording and alarm notifications. In addition to the 0 V DC reference point and power (DC
output), the I/O connector provides the interface to:
Digital output — For connecting external devices such as relays and LEDs. Connected devices can be activated by the
VAPIX® Application Programming Interface, output buttons on the Live View page or by an Action Rule. The output
will show as active (shown under System Options > Port & Devices > Port Status) if the alarm device is activated.
Digital input — An alarm input for connecting devices that can toggle between an open and closed circuit, for
example: PIRs, door/window contacts, glass break detectors, etc. When a signal is received the state changes and
the input becomes active (shown under System Options > Port & Devices > Port Status).
1
2
3
4
5
6
Function
DC Output
GND
Configurable
(Input or Output)
1
GND
2
DC output 12 V, max 50 mA
A
I/O configured as input
B
I/O configured as output

Axis 10-pin Push-Pull System Connector (sold separately)

When connecting external equipment to the Axis product, an Axis 10-pin Push-Pull System Connector (sold separately) is required in
order to maintain the product's IP rating.
Pin
Notes
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
1
Ground
Digital input – Connect to pin 8 to activate, or leave
3 – I/O 1
floating (unconnected) to deactivate.
4 – I/O 2
5 – I/O 3
Digital output – Connected to pin 8 when activated,
6 – I/O 4
floating (unconnected) when deactivated. If used with an
inductive load, e.g. a relay, a diode must be connected
in parallel with the load, for protection against voltage
transients.
1
2
A
B
67
Specifications
12 V DC
Max load = 50 mA
0 to max 30 V DC
0 to max 30 V DC, open drain,
100 mA