Haier HSU24VHJ(DB) Service Manual page 59

Wall mounted type dc inverter ea-series
Hide thumbs Also See for HSU24VHJ(DB):
Table of Contents

Advertisement

7.3.5 Thermistor or Related Abnormality(outdoor unit)
Frost-removing temperature sensor failure
Indoor display:
outdoor display:
Exhaust temperature sensor failure
Indoor display:
outdoor display:
Ambient temperature sensor failure
Indoor display:
outdoor display:
Suck temperature sensor failure
Indoor display:
outdoor display:
Method of
This type of error is detected by checking the thermistor input voltage to the microcomputer.
Malfunction
(A thermistor error is detected by checking the temperature)
Detection
Malfunction
The thermistor input is above 4.9V or below 0.1V with the power on.
Decision
Conditions
* Note: The values may vary slightly in some models
Supposed
Causes
Troubleshooting
* Caution Be sure to turn off power switch before connect or disconnect connector,
Check the connector connection.
Is it normal?
Thermistor resistance check
Is it normal?
Replace the outdoor unit PCB
HSU24VHJ DB
F21
LED1 flash 10 times:
F25
LED1 flash 13 times:
F6
LED1 flash 12 times:
F7
LED1 flash 11times:
Faulty connector connection
Faulty thermistor
Faulty PCB
else parts damage may be occurred.
YES
YES
NO
Correct the connection
NO
Replace the thermistor
57
Service Diagnosis
Domestic Air Conditioner
or

Advertisement

Table of Contents
loading