Quick Exit: [✱] + [6] + [Access Code] + [1]; Auto Arm Control: [✱] + [6] + [Access Code] + [2]; Keypad Setup: [✱] + [6] + [Access Code] + [3]; Bell/Comm Test: [✱] + [6] + [Access Code] + [4] - DSC maxsys PC4020KT System Manual

Table of Contents

Advertisement

Quick Exit
[✱]+[6]+[Access Code]+[1]
The "Quick Exit" function is enabled by toggling to "Y"
on the keypad. When enabled the user can exit through
any delay zone without altering the status of the system,
by entering [✱]+[0] on the keypad while the system is
armed.
Auto Arm Control
[✱]+[6]+[Access Code]+[2]
The Auto Arm Control options can only be accessed if
Auto Arm is enabled for the partition. The PC4020 can
be programmed to arm a partition at the same time each
day, by enabling the Auto Arm function and
programming the Auto Arm time.
At the selected Auto Arm time, the system will give a
pre-alert. The keypad buzzer begins to sound and the
Bell/Siren will pulse once every 10 seconds to alert
anyone on the premises that the system is about to arm.
The Bell/Siren pulse can be disabled in Installer's Mode.
The keypad buzzer will sound for one minute before
Auto Arming unless the Auto Arm is aborted. To abort
the Auto Arm and silence the keypad press any key
during the pre-alert. The Auto Arm will be attempted at
the same time the following day. The PC4020 can be
programmed to require a code to be entered for a user
to abort the Auto Arm.
Upon selecting the Auto Arm Control function, the Auto
Arm Control menu will appear on the LCD keypad.
[0] Auto Arm
[1]Schedule Arm
[3] Sched Disarm
[0] Auto Arm toggles "Y" or "N" to enable or disable
the Auto Arm/Auto Disarm function.
[1] Schedule Arm when this toggle option is enabled
the partition will follow the Auto Arm schedule
programmed (by the installer) for that partition. When
this option is enabled the partition will not follow the
Auto Time (programmed in section 2). For the Auto Arm
Time to function this option must be disabled.
[2] Auto Arm Time is the time the partition will
automatically arm itself every day.
[3] Sched. Disarm when this toggle option is enabled
the partition will follow the Autodisarm schedule
programmed (by the installer) for that partition.
Note: The Auto Arm time is a 24 hour clock and times
must be entered as two digit numbers.
E.g. HH - 01, 02,.....10,11,.....23,24
MM - 00, 01,.....35,36.....58,59
Enter 4 digits representing the time in hours and minutes
(HH:MM) based on 24 hour or military time. Always enter
a leading zero where only one digit is required, 8:05 am
would be entered as 0805, 1:30 pm would be entered as
1330.
Keypad Setup
[✱]+[6]+[Access Code]+[3]
This function allows the user to adjust the backlighting
and contrast of each LCD4500 keypad. When this
function is selected, the Keypad Setup menu will appear on
the keypad.
• Bright Control adjusts the level of backlighting on
• Contrast Control adjusts the contrast of the lettering
Use the [<][>] keys to toggle through the eight different
settings, and press [✱] to select the level of preference.
Note: To adjust the keypad brightness and contrast
control of a global keypad, the keypad must first be
loaned to a partition.
Bell / Comm Test
[✱]+[6]+[Access Code]+[4]
This option allows the end user to test the system. This
option activates all outputs programmed for 'Fire and Burg',
'Inv Fire/Burg', 'Burg Only' and 'Inv Burg Only' for two
seconds, sounds the keypad's for 2 seconds, tests the
main board and PC4204 battery voltage, and sends a test
code transmission to the monitoring station.
Door Chime
[✱]+[6]+[Access Code]+[5]
The Door Chime feature is enabled or disabled on a
partition by pressing the [✱] key to toggle from "N" to "Y"
or "Y" to "N". When the door chime feature is enabled, any
zone that has been selected as chimeable will cause the
keypad to beep 5 times each time the zone opens or
restores while the partition is disarmed (Note that Fire zones
and 24 hour zones are never disarmed, therefore they can
never chime).
[2] Auto Arm Time
See "Chime Function" in the Programming Manual to enable
a zone to use the chime function. While disarmed zone
bypass may be used to eliminate the beeping.
Spec. Messages
[✱]+[6]+[Access Code]+[6]
This function enables 4 special event messages to be
displayed when one of the special events occurs.
The first message is "System Has Failed To Arm". It will be
displayed if the user is unable to arm the partition after
entering a valid code (E.g. Because of activity on the
zones.).
The second message is "Alarm Occurred While Armed". It
will be displayed if an alarm occurred during the previous
armed period.
The third message is "Fire Alarm !!! 2 Wire Smoke", this
message will only be displayed if the 2 wire smoke detector
on the PC4700 fire module goes into alarm.
The fourth message is "Fire Alarm !!! Waterflow Sensor", this
message will be displayed if the waterflow detector on the
PC4700 fire module goes into alarm.
Note: If there is more than one of these fire messages to
be displayed at once the messages will scroll one every
three seconds to the next message.
Once any fire alarm has been silence a message "Fire Bell
Has Been Silenced" will be displayed on the partition and
global keypads until the partition is armed.
The fifth message is "Zone Fault will occur". It will be
displayed if the zone loop is shorted while using Double
EOL resistors.
24