Logical Disk 1
Operating System Volume
Logical Disk 2
DON'T ERASE Volume
Physical Disk 0
Figure 15 DL380 G5 hardware RAID
Table 11
provides additional information about the drive configuration.
Table 11 DL380 G5 two-HDD configuration
Logical
disk
1
2
NOTE:
In the HP Array Configuration Utility (ACU), logical disks are labeled 1 and 2. In Disk Manager,
logical disks are displayed as 0 and 1. The ACU user guide is available for download at
http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00294139/c00294139.pdf. For
HP Smart Array configuration information, the P400 controller user guide can be obtained from
http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00572169/c00572169.pdf.
NOTE:
The DON'T ERASE logical disk supports the recovery process only and does not host the secondary
operating system. If you need to perform a system recovery for your server, see the instructions inside the
HP ProLiant Storage Server System Installation and Recovery DVD. Be sure to back up your user data,
and then use the DVD to restore the server to the factory default state.
Data volumes are not carved at the factory or by the System Installation and Recovery DVD, and must be
configured manually by the end user.
If the operating system has a failure that might result from corrupt system files, a corrupt registry, or the
system hangs during boot, refer to
Be sure to back up your user data, and then use the System Installation and Recovery DVD to restore the
server to the factory default state as soon as conveniently possible.
External storage drives
The MSA20 storage enclosure for the DL380 G5 2 TB Storage Server is configured for hardware RAID
fault tolerance using the HP Smart Array 6402 RAID Controller. The SATA HDDs are hot-pluggable and
hot-swappable.
RAID 1
RAID 1
Physical Disk 1
gl0058
RAID level
Size/allocation
RAID 1
15 GB across physical drive
0, 1
RAID 1
5 GB across physical drive 0,
1
"System installation and
Purpose
Primary OS
DON'T
ERASE
recovery" on page 143.
HP ProLiant DL380 G5 Storage Server