On the same page, the operation mode of the built-in fans
can also be selected.
Voltage confirmation/Fan Operation mode select
page
1
11.4V
FAN:AUTO1
At 1 and 2 on the first line, the values in voltage of the
12-V and 24-V power systems are displayed, respectively.
If power is not supplied, "- -" is displayed.
If the voltage falls to the NEAR END level, the indication
starts flashing. If the voltage falls further down to the END
level, the indication flashes rapidly.
The NEAR END and END levels can be set on the <BATT
ALARM SET> page of the MAINTENANCE menu.
Selecting Fan Operation mode
On the second line, the operation mode of the built-in fans
can be changed according to the ambient temperature or
the operation mode of the recorder.
Setting
Operation of the fans
AUTO1 (default)
The fans are automatically controlled
according to the internal temperature.
During recording, the fans are
controlled for a quiet condition.
Normally use this mode.
AUTO2
The fans are normally controlled as
those in MIN mode and for a quieter
condition during recording.
recording time must be limited to a short
duration. Use this mode only under
ordinary ambient temperature.
MIN
The quietest fan operation is maintained
without synchronization with recording.
This is the best mode if recording must
be made for more than 30 minutes in a
quiet condition such as a concert hall.
Use this mode only under ordinary
ambient temperature.
MAX
The fans rotate at the maximum speed
to lower the internal temperature.
1) The control in synchronization with recording is valid only when the SRW-
1 is directly docked on the camera or is optically connected to the camera
via the CA-F101. The RUN indicator of the camera then lights.
Notes
• If the internal temperature rises so high that the
TEMPERATURE CARE message is displayed, the fan
rotation speed will automatically increase to lower the
temperature.
• If the internal temperature rises so high that the TEMP
WARNING/FAN MAX message is displayed, the Fan
Operation mode setting is automatically changed to
2
24.1V
1)
1)
Note that
MAX. After the temperature is sufficiently lowered and
the message disappears, manually restore the original
mode.
• When the video format is set to 50P, 59.94P, S50P,
S59.94P, or S60P, the fans are controlled as in AUTO1
mode even if AUTO2 or MIN mode has been selected, so
that any rise in internal temperature due to an increase in
power consumption will be suppressed. The control
function in synchronization with recording does not
operate in this condition.
To change Fan Operation mode using the menu
You can also change Fan Operation mode (FAN MODE)
by using the <OTHERS 1> page on the USER
(MAINTENANCE) menu (page 80).
3-2-10 ON/OFF of the Character
Indication
Superimposition of character data onto camera images can
be activated or deactivated by output destination.
Character indication setting page
VF1:ON
MON:ON
VF1
Viewfinder connected via the VF1 connector (default: ON)
VF2
Viewfinder connected via the VF2 connector (default: ON)
MON
Monitors connected via the MONITOR OUT HD SDI
connectors (default: ON)
VBS
Monitors connected via the TEST OUT and REMOTE
connectors (default: ON)
3-2-11 Allocation of Functions to
the Assignable Buttons and Switch
Various functions can be allocated to assignable buttons 1
to 3 and assignable switch 4 (the upper position of the 4/
AUTO BLK BAL switch) that are located on the side of the
camera and on the assistant panel.
At shipment, the ND-filter select function is allocated to
button 1, and the CC-filter select function is allocated to
button 2. No function is allocated to button 3 and switch 4.