2-4 Attaching a Lens

Use an appropriate optional lens that conforms to the B4
(2/3") lens mount.
For information on handling lenses, refer to the lens'
operation manual.
1
Pull the lens fixing lever upwards and remove the lens
mount cap from the lens mount.
V F 1
C TR L
V F 2
2
Align the lens' alignment pin with the notch in the
upper part of the lens mount and insert the lens (sold
separately) into the mount.
3
While supporting the lens, push the lens fixing lever
downward to secure the lens.
1 5
1 2
When a lens with a lens cable has been mounted, connect
the cable to the LENS connector located at the lower left
of the lens mount.
22
Attaching a Lens
3
2
1
R
FIL TE
R
CL EA
1
ND
2
1/4
D
1/1 6N
D
3
1/6 4N
4
CA P
5
K
TA TU
56 00
NC EL /S
A
32 00
K
B
K
43 00
LA Y CA
C
63 00
K
D
U/ DI SP
1/2
ND
E
VF M EN
LO C K
R U N
S E T
4
PA G E
AU TO
BL K
BA L
P R O
Lens fixing lever
V F 1
3
2
1
C TR L
FIL TE
R
R
CL EA
1
ND
1/4
D
2
1/1 6N
3
D
1/6 4N
4
CA P
5
56 00
K
TA TU
A
K
NC EL /S
32 00
B
43 00
K
LA Y CA
C
K
63 00
D
ND
U/ DI SP
E
1/2
VF M EN
LO C K
R U N
S E T
4
PA G E
AU TO
V F 2
BL K
BA L
8
P R O
Notch
Selecting a lens file
With this camera, values, such as the compensation values,
which are specific to the mounted lens can be registered in
a lens file. You can perform necessary adjustments upon
replacement of lenses by merely invoking the registered
file.
When you remounted a non-serial lens for which a lens file
has been registered, select the file using the subdisplay.
For lens file selection on the subdisplay, see "3-2-7
Selection of a Lens File" (page 36).
If the mounted lens is a serial lens, the corresponding lens
file will be automatically invoked.
For details on the lens files, see "5-1 File Configuration"
(page 91).
Adjusting the flange focal length
Adjustment of the flange focal length
following situations:
• The first time a lens is attached
• When changing lenses
• When zooming, and the focus is not sharp at both
telephoto and wide angle
Note
The parts of the lens used in adjusting the flange focal
length are in different positions on different lenses. Refer
to the lens' operation manual.
The procedure for adjusting the flange focal length is as
follows:
About 3 meters
(10 ft)
1
Set the iris control to manual and open the iris fully.
2
Place a flange focal length adjustment chart
approximately 3 meters from the camera and adjust the
lighting to get an appropriate video output level.
3
2)
Loosen the Ff
ring lock screw.
4
With either manual or power zoom, set the zoom ring
to telephoto.
1)
is necessary in the

Advertisement