Vco And Rx Adjustment Specification; Tx Adjustment Specification - Alinco DR-235 Service Manual

Hide thumbs Also See for DR-235:
Table of Contents

Advertisement

2) VCO and RX Adjustment Specification

ITEM
CONDITION
Adjustment
145.90MHz
Frequency
TX
VCO
136.00MHz
Adjustment
RX
VCO
173.99MHz
Confirmation
RX
Rx Signal
146.05MHz
Sensitivity
Adjustment
136.05MHz
146.05MHz
173.95MHz
Squelch
146.05MHz
Adjustment
SSG OFF
Indication 01
S Meter
146.05MHz
Adjustment
SSG20dBu 1KHz
3.5KHz/DEV

3) Tx Adjustment Specification

ITEM
CONDITION
HI POWER
146.00MHz
Adjustment
HI POWER
MID POWER
146.00MHz
Adjustment
MID POWER
LOW POWER
146.00MHz
Confirmation
LOW POWER
Maximum
146.00MHz
Deviation
MOD
Adjustment
1KHz40mVemf
WIDE
Maximum
146.00MHz
Deviation
MOD
Adjustment
1KHz40mVemf
NARROW
Mic Gain
146.00MHz
Adjustment
MOD
1KHz4mVemf
WIDE
CTCSS
146.00MHz
Modulation
88.5Hz
Level
Confirmation
DCS
146.00MHz
Modulation
255 Code
Level
Adjustment
1750Hz
146.00MHz
Modulation
1750Hz
Level
Confirmation
DTMF
146.00MHz
Modulation
DTMF
Level
Press the V/M
Confirmation
key during TX
UNIT
ADJ.SPOT
MAIN
TC101
MAIN
L123
MAIN
MAIN
L105, L104
L103, L102
MAIN
VR101
MAIN
VR102
UNIT
ADJ.SPOT
MAIN
VR103
MAIN
VR104
MAIN
MAIN
VR107
MAIN
VR105
MAIN
VR106
MAIN
MAIN
VR108
MAIN
MAIN
1
ADJUSTING METHOD
Adjust so that Tx Frequency
becomes within 145.90MHz±100Hz
Adjust so that PD voltage becomes
1.5V
Confirm if PD voltage becomes less
than 7.3 V
Repeatedly adjust so that the Rx
sensitivity becomes in maximum.
Confirm:
At -7dBu SINAD more than 12dB
At -8dBu SINAD more than 12dB
At -6dBu SINAD more than 12dB
Adjust so that the squelch stops at
perfectly close location
Adjust so that all the indicator
appears
ADJUSTING METHOD
Adjust to 50.0±1.0W
Adjust to 10.0±1.0W
Confirm if it becomes 4.0 ±1.0W
4.5±0.1KHz/DEV
2.2±0.1KHz/DEV
3.0±0.1KHz/DEV
800±200Hz/DEV 3KHz LPF ON
800±50Hz/DEV 3KHz LPF ON
3.0±0.5KHz/DEV
3.0 ±0.5KHz/DEV
47

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dr-135Dr-435

Table of Contents