Introduction; Safety Warnings - Triton TW10i Installation And Operating Instructions Manual

Handwash
Table of Contents

Advertisement

INTRODUCTION

This book contains all the necessary fitting and
operating instructions for your Triton TW10i water
heater. Please read them carefully.
The heater installation must be carried out by a
suitably qualified person and in the sequence of
this instruction book.
Care taken during the installation will ensure a
long and trouble-free life from your water heater.
Important: All plumbing connections must be
completed before making the electrical
connections.
SPECIFICATIONS
Electrical (UK only):
Nominal power
rating at 240V
9.5kW – (40A MCB rating)
Electrical (export only):
Nominal power rating at 230V
8kW – (35A MCB rating)
Nominal power rating at 230V
6kW – (30A MCB rating)
Water inlet connection:
15mm diameter 1/2" BSP nut and compression
olive supplied.
Water outlet connection:
15mm diameter 1/2" BSP nut and compression
olive supplied.
Entry points:
Water – bottom.
Cable – top or back.
Materials:
Backplate - zinc plated mild steel.
Cover – flame retardant ABS.
Elements – Minerally insulated corrosion resistant
metal sheathing.
Dimensions (in millimetres):
Height - 188; Width - 295; Depth - 85
When installed in accordance with this
installation/instruction book, the TW10i unit
then complies with the following standards
and approvals:
Splashproof rating IPX4
TW10i
Nominal power
rating at 230V
8.7kW – (40A MCB rating)
Complies with requirements of current British and
European safety standards for household and
similar electrical appliances'.
Meets with Compliance with European
Community Directives (CE).
ADVICE TO USERS
A The electric heating elements operate at a
constant rate. It is the flow rate of the water
passing through the heater which determines the
water temperature – the slower the flow, the
hotter the water becomes and the faster the flow,
the cooler the water.
B The heater can provide sufficient hot water for
handwash purposes or low fill rates to a sink. If
connected to two taps, they should not be
operated simultaneously. During Winter, mains
cold water entering the unit will be cooler than in
Summer. Therefore the flow rate of hot water will
vary between seasons.
C Switch off immediately at the isolating switch if
water ceases to flow and contact Triton Customer
Service.

SAFETY WARNINGS

1 The heater MUST NOT be used if suspected of
being frozen.
2 Switch off immediately at isolating switch if
water ceases to flow during use.
3 If it is intended to operate the heater in areas of
hard water it is advisable to fit a scale inhibitor
(contact Triton for advice).
4 A thermal cut-out device is fitted to the
elements to protect the unit under faulty
conditions.
If cut-out operates, see 'Operating Functions'
(overheat cut-out) or contact Triton Customer
Service for advice.
Due to continuous improvement and updating,
specification may be altered without prior notice.
Replacement parts can be ordered from Triton.
See 'spare parts' for details and part numbers.