Water Heater Bypass Valve
-Typical installation shown
(See "Water System Drain Valve Locations" chart
at the end of this section for location on your model)
3. Insert the end of the siphon tube (located at
front of galley behind access door) into a pail
or other container with 2 to 3 gallons of non-
toxic RV antifreeze solution.
• Antifreeze Siphon Tube
Antifreeze Siphon Tube/Winterization Port
(Located front of galley behind access door)
4. Turn Winterization Valve 2 (located near the
sliding entrance door) to the "Winterize"
position.
• Winterization Valve
Winterization Valve 2
(Located near the sliding entrance door)
NOTE: Ensure that all drain valves are
CLOSED before pumping RV antifreeze
into the water system.
Refer to the "Water System Drain Valve
Locations" chart at the end of this
section for valve locations on your
model.
Fill Lines
5. Turn the Water Pump switch ON.
6. Open each hot and cold water faucet handle/
knob in the coach - one at a time each in turn
until antifreeze solution just begins to flow
from the faucet, then close.
Do not forget the exterior shower/wash station
knobs.
7. Press the toilet flush pedal and hold until
antifreeze begins flowing into the toilet.
Leave small amount of antifreeze that remains
in the bowl.
When Done Adding RV Antifreeze
8. Turn Water Pump switch OFF.
9. Turn Winterization Valve 2 to the "Normal"
position.
This will stop the flow from the Antifreeze
Siphon Tube and revert the tank line flow to
the water pump.
10. Replace the protective cap onto the end of the
Antifreeze Siphon Tube to keep out insects
and debris when not in use.
SECTION 7 –