Gas Supply Connection Requirements - Haier HLTD600AEW User Manual

Table of Contents

Advertisement

Available languages

Available languages

GAS SUPPLY REQUIREMENTS
NOTE: The gas service to the dryer must conform with local codes and ordinances
and the latest edition of the National Fuel Gas Code, ANSI Z223.1 or in Canada,
CAN/CGA B149.1.
Natural Gas
The dryer is equipped for use with Natural gas.
LP (Liquid Propane) Gas
The dryer can be converted for use with LP gas.
Conversion to LP gas must be made by a qualified technician.
Gas Supply Line
The gas supply line should be ½" (1.3 cm) pipe and must have an individual
manual shutoff valve installed within 6 ft (183 cm) of the dryer in accordance with
the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or in Canada with the Natural
Gas and Propane Installation Code, B149.1.
The shutoff valve should be easy to reach for opening and closing.
A ⅛" NPT minimum plugged tapping, accessible for test gage connection, must
be installed immediately upstream of the gas supply connection to the dryer.
The supply line should terminate with a ⅜" NPT flare adapter fitting.
a
½" NPT Gas Supply Line
b
Gas Shutoff Valve
c
⅛" NPT Minimum Plugged Tapping
d
⅜" NPT Flare Adapter Fitting

GAS SUPPLY CONNECTION REQUIREMENTS

This dryer must be connected to the gas supply line with a listed flexible gas
connector that complies with the standard for connectors for gas appliances, ANSI
Z21.24 or CSA 6.10.
Flexible stainless steel gas connector:
If local codes permit, use a new flexible stainless steel gas connector (Design
Certified by the American Gas Association or CSA International) to connect your
dryer to the rigid gas supply line. Use an elbow and a ⅜" flare x ⅜" NPT adapter
fitting between the stainless steel gas connector and the dryer gas pipe, as
needed to prevent kinking.
12
B
C
A
D

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hltd600agwHltd600acw

Table of Contents