Advertisement

BDV Series Direct Vent Gas Fireplace
GlAss FRAMe ReMoVAl
1. Release two clamps on bottom of fireplace. Figure 59
. Tilt glass frame out and lift glass frame up until it clears three tabs on
top of fireplace.
3. Set glass frame aside.
Glass Frame
each clamp has a quick spring force. When
reinstalling clamps, keep fingers clear.
Remove control panel to operate middle
clamp on 500 and 600 units.
44
Clamps
Two () on 300/400 Units
Three (3) on 500/600 Units
Figure 59 -
Remove Glass Frame
FP2104
BDV remove glass

GlAss ReMoVAl

FP104
Three Tabs
WARNING
!
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
54D0700