Heatrae Sadia Megaflo solar Installation Manua page 33

Fitting and using the megaflo solar unvented mains pressure water heater
Table of Contents

Advertisement

Table 3 - Dimensions
SIZE
TYPE
170
Direct
190
Indirect
210
Direct
210
Indirect
260
Direct
Indirect
250
Direct
300
300
Indirect
Table 4 - Direct units - Technical specifications
UNIT WEIGHT (kg)
SIZE
EMPTY
170
37.8
210
42.5
260
47.3
300
61.5
Table 5 - Indirect units - Technical specifications
UNIT WEIGHT (kg)
SIZE
EMPTY
FULL
190
45.5
235.5
210
47.5
257.5
250
56.5
306.5
300
66.5
366.5
NOTE
Coil heating performance based on a primary flow rate of 15 l/min at 80
Temperature rise is from 15
Heating times using the solar primary circuit will depend on the amount of solar radiation, sun-
shine hours, collector panel type, size and orientation so will be variable.
A
B
1205
-
1372
-
1473
1000
1473
-
1777
1130
1731
-
2038
1409
2038
-
AUXILLARY
VOLUME (L) LOWER (3kW)
FULL
120
207.8
140
252.5
170
307.3
200
361.5
AUXILLARY
SURFACE
VOLUME (L)
(sqm)
120
0.61
120
0.68
145
0.73
175
0.79
C to 60
C.
o
o
DIMENSIONS (m m )
C
D
-
744
732
803
-
759
892
808
-
842
1160
883
-
870
1438
1023
HEAT UP TIMES (mins)
UPPER +
LOWER (6kW)
126
N/A
150
75
178
89
220
110
AUXILLARY COIL SPECIFICATIONS
HEAT UP
RECOVERY
(mins)
21
21
24.5
22.5
C.
o
E
F
923
-
1019
923
1184
-
1184
1095
1439
-
1391
1258
1715
-
1715
1573
UPPER BOOST
(3kW)
N/A
60
60
60
RATING
(mins)
(kW)
14.5
18.0
14.5
18.0
20
18.7
19
24.5
33

Advertisement

Table of Contents
loading

Table of Contents