Primary Air Adjustment - Inca Metal Cutting Tasman DV Linear ESSENCE Installation And Operating Instructions Manual

26000 btu
Table of Contents

Advertisement

PILOT FLAME ADJUSTMENT
For proper operation, the pilot and main burner flames must be steady and not lifting off or floating. The
top 3/8
1/2 (10-13mm) of the thermocouple should be engulfed by the pilot flame.
3.3.8 PRIMARY AIR ADJUSTMENT / AJUSTEMENT DE L'AIR PRIMAIRE
Aeration is factory set but may need adjustment for altitude or movement during shipping. / L'aération est
réglée en usine, mais peut nécessiter un ajustement de l'altitude ou le mouvement pendant le transport.
To adjust the air shutter / Pour ajuster l'obturateur d'air
1/. Turn off the gas / Fermez le gaz
2/. Remove the door / Enlevez la porte
3/. Remove glass from burner / Retirez le verre du brûleur
4/. Remove the burner pan by undoing the screws at front and back of pan. Remove the burner carefully
(rocks can be left on pan if removal is done with care). / Retirer la casserole du brûleur en dévissant les
vis à l'avant et l'arrière du poêle. Retirez le brûleur avec soin (roches peuvent être laissés sur poêle si
l'enlèvement est fait avec soin)
5/. Undo the set screw on the air shutter and adjust accordingly then retighten the set screw. / Défaire la
vis de réglage sur le volet d'air et d'ajuster en conséquence, puis resserrez la vis de réglage.