PERFORMANCE
DATA SHEET
Water Filtration System
Model
P5WB12NL/P4RFWB12
Capacity
120 Gallons
(455 Liters)
System
tested and certified
by NSF International
against
NSF/ANSI
Standard
42 for the reduction
of Chlorine
Taste and Odor, and Particulate
Class I*; and against
NSF/ANSl
Standard
53 for the reduction
of Live
Cysts, Asbestos,
Lead, Lindane, Toxaphene,
Atrazine,
and 2,4 - D.
This system
has been tested
according
to NSF/ANSl
Standards
42 and 53 for the reduction
of the substances
listed below. The
concentration
of the indicated
substances
in water entering
the system was reduced
to a concentration
less than or equal to the
permissible
limit for water leaving the system,
as specified
in NSF/ANSl
Standards
42 and 53.
Substance
Reduction
Aesthetic
Effects
Chlorine Taste/Odor
Particulate Class I*
Contaminant
Reduction
Live Cysts t
Asbestos
Lead: @ pH 6.5
Lead: @ pH 8.5
Lindane
Toxaphene
Atrazine
2,4 - D
NSF Reduction
Requirements
50% reduction
85% reduction
NSF Reduction
Requirements
99.95%
99%
0.010 mg/L
0.010 mg/L
0.0002 mg/L
0.003 mg/L
0.003 mg/L
0.07 mg/L
Average
Influent
2.0 mg/L
7,300,000 #/mL
Average
Influent
160,000/L
87 MFL
0.160 mg/L
0.140 mg/L
0.0019 mg/L
0.014 mg/L
0.0094 mg/L
0.220 mg/L
Influent Challenge
Concentration
2.0 mg/L _+10%
At least 10,000 particles/mL
Influent
Challenge
Concentration
50,000/L rain.
107to 108fibers/L tt
0.15 mg/L + 10%
0.15 mg/L_+ 10%
0.002 mg/L _+10%
0.015 mg/L _+10%
0.009 mg/L_+ 10%
0.210 mg/L_+ 10%
Maximum
Effluent
0.20 mg/L
75,000 #/mL**
Maximum
Effluent
54/U
0.17 MFL
0.001 mg/L
0.005 mg/L
0.00002 mg/L
0.001 mg/L
0.0005 mg/L
0.028 mg/L
Minimum %
Reduction
97
99
Minimum %
Reduction
99.97
99
99.4
98.6
98.9
93
94.5
87.5
Test Parameters:
pH = 7.5 + 0.5 unless otherwise
noted.
Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service
capacity
= 120 gallons
(455 liters).
It is important that operational, maintenance,
and filter
replacement requirements
be carried out for the product to
perform as advertised. Property damage can occur if all
instructions
are not followed.
Use replacement filter P4RRWB/P4RFWB12,
part
#W10295370. 2012 suggested retail price of $49.99 U.S.A./
$59.99 Canada. Prices are subject to change without notice.
Style 1 - When the water filter status display changes from
"GOOD" to "ORDER," order a new filter. When the filter
indicator reads "REPLACE," it is recommended
that you
replace the filter.
Style 2 - When the filter indicator changes from green to
yellow, order a new filter. When the indicator changes from
yellow to red, it is recommended
that you replace the filter.
Style 3 - When the filter indicator reads 10%, order a new
filter. When the indicator reads 0%, it is recommended
that
you replace the filter.
Style 4 - For models without a water dispenser, replace the
disposable water filter every 6 months. The water filter
indicator light will remind you when it is time to change the
water filter.
After changing the water filter, flush the water system. For
filtered ice only, make and discard three full containers of ice
to prepare the water filter for use.
Average
%
Reduction
97.2
99.4
Average
%
Reduction
99.99
99
99.4
98.6
99
93
94.7
96.1
These contaminants
are not necessarily in your water supply.
While testing was performed under standard laboratory
conditions,
actual performance may vary.
The product is for cold water use only.
The water system must be installed in compliance
with state
and local laws and regulations.
Do not use with water that is microbiologically
unsafe or of
unknown quality without adequate disinfection
before or after
the system. Systems certified for cyst reduction may be used
on disinfected waters that may contain filterable cysts.
Refer to the "Warranty" section for the Manufacturer's
name,
address and telephone number.
Refer to the "Warranty" section for the Manufacturer's
limited
warranty.
Application Guidelines/Water Supply Parameters
City or Well
30 - 120 psi (207 - 827 kPa)
33 ° - 100°F (0.6 ° - 37.8°C)
0.5 gpm (1.9 Lpm) @ 60 psi
%
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
*Class I particle size: >0.5 to <1 um
**Test requirement
is at least 100,000 particles/mL
of AC Fine Test Dust.
tBased on the use of Cryptosporidium
parvum oocysts
ttFibers greater than 10 um in length
® NSF is a registered trademark