1. Use the dimensional drawings above to lay out the range hood's mounting
holes, wiring access and ductwork. Mark the cabinet bottom and drywall
where applicable.
2. Make a cutout for the wiring and duct work.
3. Install the ductwork so that it is flush with the range hood's mounting
surface.
4. Run two conductor wires from a power source to the hood location. Bring
approximately 12'' of wiring through wiring hole.
5. Drill 3/32" diameter pilot holes at the points where mounting holes are
marked.
6. Insert 4 mounting screws, leaving approximately ¼" of thread exposed.
9