Summary of Contents for COMFORT-AIRE REG-81J

  • Page 1 REG-81J REG-123J AITONS EQUIPMENT • Guelph, ON N1H 6H9 • 1-888-744-2911 • www.aitons.com...
  • Page 2 AITONS EQUIPMENT Owner’s Manual Room Air Conditioner with R-410A • Contact an authorized service technician for repair or maintenance of this unit. • Contact an authorized installer for installation of this unit. • If the power cord needs to be replaced, replacement work shall be performed by authorized service personnel only.
  • Page 3 AITONS EQUIPMENT Room Air Conditioner with R-410A Owner’s Manual To prevent injury to the user and propert damage, the following instructions must be followed. Incorrect operation due to ignoring instructions may cause harm or damage. damage. WARNING CAUTION WARNING Do not open the unit Always ensure Plug in power cord during operation...
  • Page 4 Room Air Conditioner with R-410A AITONS EQUIPMENT Owner’s Manual ! CAUTION Do not allow water to Ventilate the room well enter inside the unit when used together with removed, do not touch the during cleaning etc. a gas stove or if there is metal parts of the unit a gas leak •...
  • Page 5 AITONS EQUIPMENT Room Air Conditioner with R-410A Owner’s Manual Please refer to the section “Operation of Current Device” for details.
  • Page 6: Unit Control

    Room Air Conditioner with R-410A AITONS EQUIPMENT Owner’s Manual Unit may vibrate and make noise because of poor wall or window construction or incorrect installation. Pinging or Swishing Droplets of water hitting condenser during normal operation may cause pinging or swishing sounds. Gurgling or hissing noise may be heard due to refrigerant passing through evaporator...
  • Page 7: To Change Temperature Setting

    AITONS EQUIPMENT Room Air Conditioner with R-410A Owner’s Manual TO CHANGE TEMPERATURE SETTING: Press or hold either Temp/Timer Up ( ) or Down ) button until the desired temperature is seen on the display. This temperature will be automatically maintained anywhere between 62°F (17°C) and 86°F (30°C).
  • Page 8 Room Air Conditioner with R-410A AITONS EQUIPMENT Owner’s Manual and Fan. The indicator light beside the selected mode will illuminate and remain on once the mode is selected. To operate in Auto feature: When you set the air conditioner to AUTO mode, it will automatically select cooling, heating or fan only depending on what temperature you have selected and the room temperature.
  • Page 9 AITONS EQUIPMENT Room Air Conditioner with R-410A Owner’s Manual AIR CONDITIONER FEATURES (CONTINUED) TIMER: AUTO START/STOP FEATURE Press or hold the Temp/Timer UP or DOWN button to change the Auto time by 0.5 hour increments, up to 10 hours, then count down the time remaining until start.
  • Page 10 Room Air Conditioner with R-410A Owner’s Manual Heat Controller, Inc. AIR CONDITIONER FEATURES (CONTINUED) THE DISPLAYS * The control is capable of displaying temperature in degree Fahrenheit or degrees Celsius. To convert from one to the other, press and hold the Left and Right Temp/Timer buttons at the same time, for 3 seconds.
  • Page 11 AITONS EQUIPMENT Room Air Conditioner with R-410A Owner’s Manual Carefully inspect the location where the air conditioner will be installed. Be sure it will support the weight of the unit. coils to prevent injury. Make sure the air conditioner does not fall and remains upright during installation. Phillips screws...
  • Page 12 AITONS EQUIPMENT Owner’s Manual Room Air Conditioner with R-410A No obstalces blocking air inlets or outlets. to 36" (91.4 cm) max. Loosen (1) shipping screw from each side of the cabinet (FIG. 3).
  • Page 13 AITONS EQUIPMENT Room Air Conditioner with R-410A Owner’s Manual...
  • Page 14 Room Air Conditioner with R-410A AITONS EQUIPMENT Owner’s Manual...
  • Page 15 AITONS EQUIPMENT Room Air Conditioner with R-410A Owner’s Manual * NOTE: Do not block the louvers on the air conditioner cabinet or your unit will not perfrom properly. * SEE NOTE ABOVE * SEE NOTE ABOVE...
  • Page 16 Room Air Conditioner with R-410A AITONS EQUIPMENT Owner’s Manual • It is recommended to use 1" (2.5 cm) or thicker lumber for wood frame. For through-the-wall installations, if needed, install molding (not provided) around the room side of cabinet.
  • Page 17 AITONS EQUIPMENT Room Air Conditioner with R-410A Owner’s Manual 104°F (40°C)
  • Page 18 Room Air Conditioner with R-410A AITONS EQUIPMENT Owner’s Manual Before calling for service, review this list. It may save you time and unnecessary expense. This list includes common occurrences that are not the result of defective workman-ship or materials in this appliance. Problem Solution Blown fuse or circuit breaker has tripped.
  • Page 19 AITONS EQUIPMENT Room Air Conditioner with R-410A Owner’s Manual Problem Solution Deactivating Prematurely...
  • Page 20 AITONS EQUIPMENT • Guelph, ON N1H 6H9 • 1-888-744-2911 • www.aitons.com 2020213A1105 11/201...

This manual is also suitable for:

Reg-123j