Check Method - GFS 1000 Safety & Operation Manual

Gas concrete nailer
Table of Contents

Advertisement

Operator troubleshooting
PROBLEM
Nailer operates,
but no nail is driven.
Skipping nails.
Intermittent feed.
Nail jam.
Driven nail is bent.
The operation of the
push lever not smooth.
Fan is working, light indicator
shows GREEN yet it doesn't
drive a nail or operation
unstable.
Fan does not operate
when push lever is pressed.
Unable to charge battery
or red light blink.

CHECK METHOD

Check for a jam nails.
Check for proper nails.
Check for a jam .
Check function of nail feeder .
Ribbon spring weakened
or damaged?
Check if the driver blade
piston is down or not.
Check for proper nails.
Check function of nail feeder.
Ribbon spring weakened or damaged.
Nail feeder weakened or damaged?
Check for returning of piston.
Check for moving of piston smoothly.
Check for proper nails.
Driver blade worn?
Nail feeder worn or damaged?
Push lever bent?
Check push lever's moving track, debris?
Check for returning of piston.
Check fuel cell, insufficient?
Check spark plug wire, worn out?
Check high pressure cap joint insert
to the spark plug.
Check spark plug, grease or debris?
Check filter, clogged?
Magazine empty.
Note the color of the light indicator.
Inspect if the battery temperature within Wait the battery temperature as
require range 50°F( 10°C) ~ 104°F (40°C).
Check if all joints are inserted
and the battery pack Insert in place.
Utility voltage not nearly of rated
voltages shown on adapter nameplate. charge. If also can not charge, contact
CORRECTION
Clear a jam nails.
Use only recommended nails.
Clear a jam.
Clean and lubricate.
Replace Ribbon spring.
Push the driver blade with a
slotted-head screwdriver, and put
back the piston to the highest position.
Use only recommended nails.
Clean and lubricate.
Replace Ribbon spring.
Replace nail feeder.
Too low temperature, warm up
fuel cell under 50 (120 ).
Replace piston assembly.
Use only recommended nails.
Replace piston assembly.
Replace nail feeder.
Replace push lever.
Clean the foreign body.
Pull the trigger all the way.
Too low temperature, warm up
fuel cell under 50 (120 ).
Exchange it with a new fuel cell.
Contact GFS for replacement
High pressure cap joint insert
to the spark plug.
Clean the foreign body.
Cleaning or Contact GFS for
replacement.
Load more nails(more than 4 nails)
in the magazine.
If red: charge the battery.
If green: Contact GFS for replacement.
the normal range then to charge.
I nsert all plugs and ensure the
battery pack insert in place.
Select and use correct utility voltage to
GFS for replacement.
18